LV Power Cable|Oil Gas Petrochem Spec

SINGLE CORE ARMOURED / UN-ARMOURED

Low voltage single core: FROR (Flame Retardant Oil Resistant) – Core size 50 – 1000mm²

Type| CU/XLPE/PVC/(AWA) FROR-PVCBedding| PVC Compound
Standard| IEC 60502-1Armouring| AWA or Un-Armoured
Rated Voltage| 0.6 / 1KVJacketing| FROR PVC Compound
Conductor| Copper WiresFlame Retardant| IEC 60332-3 CAT C
Insulation| XLPE CompoundTemp. Rated| 90°C

Low Voltage Power Cable 0.6/1KV temperature rated 90°C manufactured in accordance with IEC 60502-1. Stranded plain annealed copper conductor, XLPE insulated, PVC bedding and FROR outer sheath. Armoured cables constructed with Aluminum Wire Armour (AWA). Application: Can be used in cable tray, conduit or direct burial installations in suitably constructed ducts or trenches in wet and dry locations. Flame Retardant to IEC 60332-3 CAT C, UV and abrasion resistant, standard core color as indicated above.

2, 3, 4 and 5 CORE ARMOURED, SIZE 1.5-16MM²

Low voltage multi core armoured: FROR (Flame retardant oil resistant)

Type| CU/XLPE/PVC/SWA/FROR-PVCBedding| PVC Compound
Standard| IEC 60502-1Armouring| SWA Armoured
Rated Voltage| 0.6 / 1KVJacketing| FROR PVC Compound
Conductor| Copper WiresFlame Retardant| IEC 60332-3 CAT C
Insulation| XLPE CompoundTemp. Rated| 90°C

LV_O&G_1

Low Voltage Power Cable 0.6/1KV temperature rated 90°C manufactured in accordance with IEC 60502-1. Stranded plain annealed copper conductor,
XLPE insulated, PVC bedding and FROR outer sheath. Armoured cables constructed with Steel Wire Armour (SWA). Application: Can be used in cable tray,
conduit or direct burial installations in suitably constructed ducts or trenches in wet and dry locations. Flame Retardant to IEC 60332-3 CAT C, UV and abrasion
resistant, standard core color as indicated above.

download-21

2, 3, 4 and 5 CORE ARMOURED, SIZE 25-400MM²

Low voltage multi core armoured: FROR (Flame retardant oil resistant)

Type| |CU/XLPE/PVC/SWA/FROR-PVCBedding| PVC Compound
Standard| IEC 60502-1Armouring| SWA Armoured
Rated Voltage| 0.6 / 1KVJacketing| FROR PVC Compound
Conductor| Copper WiresFlame Retardant| IEC 60332-3 CAT C
Insulation| XLPE CompoundTemp. Rated| 90°C

MULTI CORE ARMOURED, CORE SIZE_1
Low Voltage Power Cable 0.6/1KV temperature rated 90°C manufactured in accordance with IEC 60502-1. Stranded plain annealed copper conductor, XLPE insulated, PVC bedding and FROR outer sheath. Armoured cables constructed with Steel Wire Armour (SWA). Application: Can be used in cable tray, conduit or direct burial installations in suitably constructed ducts or trenches in wet and dry locations. Flame Retardant to IEC 60332-3 CAT C, UV and abrasion resistant, standard core color as indicated above. Other colors available on request.

download-21

2, 3, 4 and 5 CORE UN-ARMOURED, SIZE 1.5-16MM²

Low voltage multi core un-armoured: FROR (Flame retardant oil resistant)

Type| CU/XLPE/PVC/FROR-PVCBedding| PVC Compound
Standard| IEC 60502-1Armouring| Un-Armoured
Rated Voltage| 0.6 / 1KVJacketing| FROR PVC Compound
Conductor| Copper WiresFlame Retardant| IEC 60332-3 CAT C
Insulation| XLPE CompoundTemp. Rated| 90°C

MULTI CORE ARMOURED, CORE SIZE_1
Low Voltage Power Cable 0.6/1KV temperature rated 90°C manufactured in accordance with IEC 60502-1. Stranded plain annealed copper conductor, XLPE insulated, PVC bedding and FROR outer sheath. Application: Can be used in cable tray, conduit or direct burial installations in suitably constructed ducts or trenches in wet and dry locations. Flame Retardant to IEC 60332-3 CAT C, UV and abrasion resistant, standard core color as indicated above.

download-21

2, 3, 4 and 5 CORE UN-ARMOURED, SIZE 25-400MM²

Low voltage multi core un-armoured: FROR (Flame retardant oil resistant)

Type| CU/XLPE/PVC/FROR-PVCBedding| PVC Compound
Standard| IEC 60502-1Armouring| None
Rated Voltage| 0.6 / 1KVJacketing| FROR PVC Compound
Conductor| Copper WiresFlame Retardant| IEC 60332-3 CAT C
Insulation| XLPE CompoundTemp. Rated| 90°C

MULTI CORE ARMOURED, CORE SIZE_1

Low Voltage Power Cable 0.6/1KV temperature rated 90°C manufactured in accordance with IEC 60502-1. Stranded plain annealed copper conductor, XLPE insulated, PVC bedding and FROR outer sheath. Application: Can be used in cable tray, conduit or direct burial installations in suitably constructed ducts or trenches in wet and dry locations. Flame Retardant to IEC 60332-3 CAT C, UV and abrasion resistant, standard core color as indicated above.

download-21

3.5 CORE ARMOURED, SIZE 25-400MM²

Low voltage 3.5 core: FROR (Flame retardant oil resistant)

Type| CU/XLPE/PVC/(SWA) FROR-PVCBedding| PVC Compound
Standard| IEC 60502-1Armouring| SWA or Un-Armoured
Rated Voltage| 0.6 / 1KVJacketing| FROR PVC Compound
Conductor| Copper WiresFlame Retardant| IEC 60332-3 CAT C
Insulation| XLPE CompoundTemp. Rated| 90°C


Low Voltage Power Cable 0.6/1KV temperature rated 90°C manufactured in accordance with IEC 60502-1. Stranded plain annealed copper conductor, XLPE insulated, PVC bedding and FROR outer sheath. Armoured cables constructed with Steel Wire Armour (SWA). Application: Can be used in cable tray, conduit or direct burial installations in suitably constructed ducts or trenches in wet and dry locations. Flame Retardant to IEC 60332-3 CAT C, UV and abrasion resistant, standard core color as indicated above.

download-21

3.5 CORE UN-ARMOURED, SIZE 25-400MM²

Low voltage 3.5 core: FROR (Flame retardant oil resistant)

Type| CU/XLPE/PVC/(SWA) FROR-PVCBedding| PVC Compound
Standard| IEC 60502-1Armouring| SWA or Un-Armoured
Rated Voltage| 0.6 / 1KVJacketing| FROR PVC Compound
Conductor| Copper WiresFlame Retardant| IEC 60332-3 CAT C
Insulation| XLPE CompoundTemp. Rated| 90°C


Low Voltage Power Cable 0.6/1KV temperature rated 90°C manufactured in accordance with IEC 60502-1. Stranded plain annealed copper conductor, XLPE insulated, PVC bedding and FROR outer sheath. Armoured cables constructed with Steel Wire Armour (SWA). Application: Can be used in cable tray, conduit or direct burial installations in suitably constructed ducts or trenches in wet and dry locations. Flame Retardant to IEC 60332-3 CAT C, UV and abrasion resistant, standard core color as indicated above.

download-21